Product Details:
Place of Origin: China
Brand Name: Dupont
Certification: CE
Model Number: SFP-2860
Document: Model SFP-2860, SFD 2860, S...80.pdf
Payment & Shipping Terms:
Minimum Order Quantity: 1 PC
Price: Negotiable
Packaging Details: standard export packing
Delivery Time: 5- 8 work days
Payment Terms: Western Union,T/T
Supply Ability: 60000 Units per Month
Contact Now
Detailed Product Description
SFP-2860 Flow Range: 2.0 – 6.1 M3 /hr SFP-2860 Flow Range Membrane Area: 51 M²
SFP-2860 Nominal Pore Diameter: 0.03 µm SFP-2860 Material: PVDF
Diameter Of This Model: 8 Inch Flow Direction Settings: External Pressure Structure, Dead End Filtration
Component NaOCl (max.): 2,000 Mg/L Component Max Backwash Pressure: 2.5 Bar
Component Main Usage: Water Treatment Pretreatment Advantages: High Filtration Accuracy
Highlight:

DuPont SFP-2860 PVDF membrane module

,

8 inch ultrafiltration membrane module

,

51 m² PVDF ultrafiltration membrane

DuPont SFP-2860 High-Flow PVDF Filtration for Industrial Wastewater Reuse
Product Specifications
Attribute Value
SFP-2860 Flow Range 2.0 – 6.1 m3/hr
SFP-2860 Membrane Area 51 m²
SFP-2860 Nominal Pore Diameter 0.03 µm
SFP-2860 Material PVDF
Diameter 8 inch
Flow Direction Settings External pressure structure, dead end filtration
Component NaOCl (max.) 2,000 mg/L
Component Max Backwash Pressure 2.5 bar
Component Main Usage Water Treatment Pretreatment
Advantages High filtration accuracy
Product Description

The DuPont UF SFP-2860 ultrafiltration module delivers robust performance in space-limited applications. Featuring PVDF hollow fiber technology with an outside-in flow configuration, it efficiently handles feed water with high solids while minimizing pretreatment needs and backwash volumes.

Key Features:
  • Precision Filtration: 0.03 μm nominal pore size removes bacteria, viruses, colloids, and particulates to protect downstream RO systems.
  • Engineered Durability: Hydrophilic PVDF fibers offer superior mechanical strength and chemical resistance (pH 2-11) for extended service life.
  • Space-Saving Design: Shorter length (1,860 mm / 73.2 in) ideal for low-ceiling installations with 51 m² (549 ft²) effective membrane area.
  • Broad Compatibility: Processes surface water, seawater, industrial wastewater, and municipal effluents.
Operating Specifications:
  • Flux Range: 40-90 LMH (24-53 gfd) at 25°C
  • Flow Rate per Module: 2.0-6.9 m³/hr (8.8-30.4 gpm)
  • Temperature Limits: 1-40°C (34-104°F)
  • Max Operating TMP: 2.1 bar (30.5 psi)
  • Chemical Tolerance: Compatible with ≤2,000 mg/L NaOCl
  • Hold-Up Volume: 35 liters (9.3 gallons)
  • Weight: 48 kg (106 lbs) empty / 83 kg (183 lbs) water-filled
Performance Guarantees:
  • Filtrate turbidity ≤0.1 NTU
  • Filtrate SDI ≤2.5
Critical Notes:
  • Installation: Requires strict adherence to DuPont UF Product Manual startup procedures.
  • Maintenance: Discard initial filtrate; max backwash pressure 2.5 bar (36 psi).
  • Compliance: Industrial grade (NSF-certified drinking water version: SFD-2860).
  • Warranty: Void if operating limits or maintenance protocols are violated.
Certifications:

NSF/ANSI 61 (if applicable), FDA compliant (for food contact, if relevant).

DuPont SFP-2860 PVDF Ultrafiltration Membrane Module 8 Inch 51 m² 0
Figure 1: SFP and SFD 2860 (8-inch diameter)
Technical Specifications
Model Type Part # Membrane Area (m²/ft²) Module Volume (Liters/Gallons) Weight (Kg/lbs)
SFP-2860 Pretreatment 280933 51 / 549 35 / 9.3 48/83 / 106/183
SFD-2860 NSF/ANSI 61 Drinking water 324168 51 / 549 35 / 9.3 48/83 / 106/183
DuPont SFP-2860 PVDF Ultrafiltration Membrane Module 8 Inch 51 m² 1
Figure 2: SFP-2860 Dimensions
Operating Parameters
Parameter SI Units US Units
Filtrate Flux @ 25ºC 40-120 l/m2/hr 24-70 gfd
Flow range 2.0 - 6.1 m3/hr 9.2 - 26.7 gpm
Temperature 1-40ºC 34-104ºF
Max. inlet module pressure (@ 20ºC) 6.25 bar 93.75 psi
Max. operating TMP 2.1 bar 30 psi
Max operating air scour flow 12 nm3/hr 7.1 scfm
Max backwash pressure 2.5 bar 36 psi
Operating pH 2-11
NaOCl (max.) 2,000 mg/L
Expected filtrate turbidity ≤0.1 NTU
Expected filtrate SDI ≤2.5
Important Information

Proper start-up of a UF system is indispensable for preparing the membranes for operational service and preventing membrane damage. Adhering to the correct start-up sequence also contributes to ensuring that the operating parameters of the system conform to the design specifications, thereby enabling the attainment of system water quality and productivity targets. Before commencing the system start-up procedures, membrane pretreatment, installation of the membrane modules, instrument calibration, and other system checks should be accomplished. Kindly refer to the product technical manual.

Operation Guidelines
  • Avoid any sudden pressure fluctuations during start-up, shutdown, cleaning or other processes to prevent potential membrane damage.
  • Flush the UF system to eliminate the shipping solution before start-up.
  • Remove the residual air from the system before start-up.
  • Manually initiate the equipment.
  • Aim for a permeate flow of 60% of the design during the initial operations.
  • Depending on the application, the permeate obtained from the initial operations should be disposed of.

Please refer to the product technical manual.

Regulatory Note

NOTICE: NSF/ANSI 61 certified drinking water modules demand specific conditioning procedures before generating potable water. Please refer to the flushing section of the product technical manual for detailed procedures. Drinking water modules might be subject to additional regulatory constraints in certain countries. Please verify local regulatory guidelines and the application status before usage and sale.

The utilization of this product does not inevitably ensure the elimination of cysts and pathogens from water. Effective reduction of cysts and pathogens depends on the complete system design as well as the operation and maintenance of the system.

Notice: No inference should be made regarding the absence of infringement of any patent owned by Dow or others. As the use conditions and applicable laws may vary from one location to another and may change over time, the Customer is accountable for determining whether the products and the information in this document are suitable for the Customer's use and for ensuring that the Customer's workplace and disposal practices comply with applicable laws and other governmental enactments. The product presented in this literature might not be available for sale and/or available in all geographical areas where Dow is represented. The claims made might not have been approved for use in all countries. Dow assumes no obligation or liability for the information in this document. References to "Dow" or the "Company" signify the Dow legal entity selling the products to the Customer unless otherwise explicitly noted. NO WARRANTIES ARE PROVIDED; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED.

Contact Details
Wuxi Fenigal Science & Technology Co., Ltd.

Contact Person: Mr. Harry

Tel: +86-13646187144

Send your inquiry directly to us (0 / 3000)