Product Details:
Place of Origin: China
Brand Name: Fenigal/OEM
Certification: CE,CCC
Model Number: FMPC
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: Negotiate
Packaging Details: Standard export carton
Delivery Time: 5-8 working days bulk order negotiate
Payment Terms: T/T, Western Union
Supply Ability: 10,000pcs/month
Contact Now
Detailed Product Description
Max. Current: 100A Max. Voltage: 400V
Pole: 2P,3P,4P Rated Voltage: 230V/400V
Rated Current: 16A 20A 25A 32A 40A 50A 63A 80A 100A Product Name: Dual Power Automatic Transfer Switch ATS
Color: White Frequency: AC 50 Hz/60Hz
Operation Type: Manual Operation,Auto&Manual Standard: IEC60947-6-1
High Light:

ATS Automatic Transfer Switch For Genset

,

250Amps Automatic Transfer Switch

,

Auto Changeover Automatic Transfer Switch

dual power automatic transfer switch(ATS) for genset, Auto changeover switch 250Amps

 

1.The dual-power automatic transfer switch (ATS) is a newly developed miniature household power transfer switch, is mainly used to test whether the main power or reserve power is normal.

When the normal power supply is abnormal, the reserve power supply will start work immediately to ensure continuity, reliability and safety of the power supply. It is specially designed for household rail installation for PZ30 distribution box.

2.The ATS is suitable for emergency power supply systems of AC50 or 60Hz and rated voltage 400V. It is featured with firm structure, reliable transfer, easy installation and maintenance, and long life, is widely used in places where frequent power outage is not allowed. Both electric and operation and manual operation are available. The ATS is composed of TES and controller.

3.According to the standard GB/T14048.11 Part 6-1: Multiple function equipment - Transfer switching equipment, we can know that ATS is the most suitable low-voltage switchgear and control device.

 

dual power automatic transfer switch(ATS) for genset,Auto changeover switch 250Amps

Splited Modular Genset Manual ATSE is composed of switch body and controller. Adopt the electromaghetic driver, the working power of controller transfer is based on the main power and the standby power. AC 220V power supply, without additional source. Switch body have an electrical or mechanical switch instruction as an isolation indicator switch.

 

Model YES1-32C YES1-40C YES1-63C YES1-125C
Rated current(A) 25,32 40 63 125
Opearting current(A) 3.5
Rated short time current(KA) 5
Service Life Mechanical 8000
Electric 3000
Pole 2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P 4P
Weight(KG) 3.2 3.7 4.2 4 4.5 5.5 4 4.5 5.5 4 4.5 5.5
Operating Cycle(s/time) 10
 

 

 

Normal running time and installation conditions

1.Ambient air temperature

Temperature should be within -5℃~40℃, and the average temperature within 24h should not exceed 35℃.

2.Altitude

Altitude of the installation site should not exceed 2000m.

3.Atmospheric conditions

The relative humidity of the installation site should not exceed 50% at maximum temperature 40℃, and it will be higher at minimum temperature -5℃, for instance, 90% at +20℃. Please take measures for the dew on product surface caused by temperature change.

4.Class of pollution

Pollution class of ATS meets the specified level of GB/T14048.11.

5.Installation category

Installation category of ATS meets the specified category in GB/T14048.11

Matterts need attention

1.Manual/automatic operation

ATS with automatic operation can ensure power generation and power-off performances, but for ATS with manual operation , it cannot ensure the above performance due to the speed of power generation and power-off or operator differences. Excessive silver alloy loss may occur during manual power generation and power down. Therefore, set the selector switch at the manual position under normal condition, and pull it to the manual position when all power is turned off to check and maintain the operating system and contacts. After the manual operation is completed pull the selector back to the automatic position.

2.Control circuit

ATS will be active in an instant. After the conversion is complete, the coils in the control circuit are disconnected by the internal converter. The coil can operate normally with a rated voltage of 80%~110%, and too low voltage may cause the coil to heat up or even ignite.

Dual Power ATS Automatic Transfer Switch For Genset Auto Changeover 250Amps 0

Dual Power ATS Automatic Transfer Switch For Genset Auto Changeover 250Amps 1

Dual Power ATS Automatic Transfer Switch For Genset Auto Changeover 250Amps 2

 

Contact Details
Wuxi Fenigal Science & Technology Co., Ltd.

Contact Person: Mr. Harry

Tel: +86-13646187144

Send your inquiry directly to us (0 / 3000)