Product Details:
Place of Origin: China
Brand Name: VEOLIA
Certification: CE
Model Number: E-Cell MK-7
Payment & Shipping Terms:
Minimum Order Quantity: 1 pc
Price: Negotiable
Packaging Details: standard export packing
Delivery Time: 5- 8 work days
Supply Ability: 60000 Units per Month
Contact Now
Detailed Product Description
Shipping Weight: 165 Kg Flow Rate Range: 5.0 – 9.0 M³/hr
Dimensions(width X Height X Depth): 30cm X 61cm X 74cm Temperature: 4.4-40 °C
Recovery: Up To 97% Nominal Flow: 7.0 M³/h (31 Gpm)
PH: 4-11
Highlight:

165kg EDI Modules

,

Continuous Electrodeionization EDI Modules

,

9 m³/hr EDI Modules

30cm x 61cm x 74cm 5-9 m³/hr VEOLIA EDI Modules E-Cell MK-7

 

E-Cell EDI Stack Features And Benefits

• Low energy consumption

• Leading product water quality, in part due to ion exchange resin filled concentrate and dilute channels as well as a patented ion exchange resin arrangement

• Counter-current operation reduces the possibility of scale formation

• Strong reputation for reliable operation

• Simplified system design does not require degassing the concentrate, a concentrate recirculation loop, or added salts

Quality Assurance
• CE, RoHS, CSA and EAC marked
• Manufactured in an ISO 9001 and ISO 14001 facility
• Certified with UKCA
• E-Cell MK-7 Stacks are Halal certified by the Islamic Food and Nutrition Council of America (IFANCA®)

 

E-Cell MK-7 Stack Specifications
Nominal Flow 7.0 m³/h (31 gpm)
Flow Rate Range 5.0 – 9.0 m³/hr
Shipping Weight  165kg
Dimensions
(width x height x depth)
30 cm x 61 cm x 74 cm

 

165kg 5-9 m³/hr  VEOLIA EDI Modules For Continuous Electrodeionization  E-Cell MK-7 0

Notes:
1. Actual performance may vary depending on site conditions. Reference Winflows projection software to verify expected product water quality as well as the resistivity, sodium, and silica performance guarantees that are offered for the design conditions. To obtain boron or other guarantees, contact Veolia.
2. Inlet pressure is determined by the downstream pressure requirements for the product and concentrate streams, the choice of counter-current or co-current operation, and stack pressure drop.
3. At nominal flow and 25°C. Reference Winflows projection software to verify for design conditions.
4. Reference the Winflows projection software and the E-Cell Stack Owner’s Manual to verify feed water specifications for the design conditions.
5. TEA (ppm as CaCO3) - Total Exchangeable Anion, this represents the concentration of all of the anions present in the feed water including contributions from OH- , CO2 and SiO2. Winflows must be used to confirm the feed water TEA is acceptable at the specific applications’ operating conditions. Table value is at minimum flow and maximum temperature.
6. 1.0 ppm as CaCO3 feed water hardness limit applies to standard counter-current flow operation only. Allowable feed water hardness decreases to 0.1 ppm as CaCO3 in co-current flow operation.
7. Allowable silica limit decreases above 5 m3 /h flow. Allowable silica limit decreases to 0.5 ppm with feedwater hardness above 0.5 ppm as CaCO3.
8. The boron feed level is limited to 0.3 ppm as B whenever there is a silica guarantee requirement or resistivity guarantee requirement above 10 MOhm-cm, as higher boron levels could impact performance. Without these requirements the limit is 1.0 ppm boron.
9. Reverse Osmosis (RO) or equivalent feed water: RO provides EDI feed water that is substantially free of particulate matter, colloidal material and high molecular weight organic substances, which can foul ion exchange media. RO permeate quality is specified since EDI stacks contain packed beds of ion exchange medium that cannot be backwashed/fluidized to remove particulate matter. Systems with an open system between a RO system (or other source) and E-Cell (ex. tank, decarbonator) must be fitted with filters immediately preceding the E-Cell, to protect the E-Cell against contamination with particulate matter. Generally, a 5 µm absolute or 1 µm nominal filter will be acceptable.
10.APHA - color standard/scale named for the American Public Health Association and defined by ASTM D1209.Veolia Water Technologies
165kg 5-9 m³/hr  VEOLIA EDI Modules For Continuous Electrodeionization  E-Cell MK-7 1

Contact Details
Wuxi Fenigal Science & Technology Co., Ltd.

Contact Person: Mr. Harry

Tel: +86-13646187144

Send your inquiry directly to us (0 / 3000)

Other Products